A Link G4X reads an exhaust gas temperature amplifier on an An Volt input, as a GP Temperature channel with a two-point linear calibration. This guide covers the inputs, the wiring, the PCLink setup, and the error limits that matter for a sensor that reads close to 0 V when cold.

Checked against Link's quick-start guides and manuals and answers from Link staff on the Link forum, September 2026. Menu names are from PCLink for G4X and G5 ECUs. G4+ ECUs use older software with different menus, so these steps won't match.

00What you need

01Pick an input

Use an An Volt input. An Volt inputs have no internal pull-up. An Temp inputs have one for thermistors, so leave those for temperature sensors. On a plug-in, use a spare An Volt on the expansion connector.

02Wire it

EGX MODULE Yellow + Red − TYPE K PROBE MINI-K SOCKET Red — supply Black — sensor ground White — analog pin TO LINK ECU
Probe on one side, three wires to the ECU on the other.
Output wires
WireEGX5EGX12
Red+5V (“+5V Out” on plug-in expansion connectors)Switched 12 V
BlackSensor ground (“Gnd Out”, or “Ground (Signal)” on plug-ins)Sensor ground (“Gnd Out”, or “Ground (Signal)” on plug-ins)
WhiteThe An Volt input you pickedThe An Volt input you picked

Probe side

03Set it up in PCLink

  1. Set up a calibration: find Linear Cal 1 in PCLink's settings tree (type “linear” in its search box). Set Label to EGT and pick Output Units. Enter Input Value A 0.000 V with Output Value A 0. Then enter Input Value B and Output Value B from the table below.
  2. Open Analog Inputs → GP Input → GP Temperature 1 and set Source to the An Volt you wired. Set its calibration to Linear Cal 1.
  3. On the An Volt, set Error Low to 0.00 V and Error High to 5.00 V, so no real reading counts as a fault. While an input is in fault, PCLink uses the Error Value instead of the reading, and so does any warning light or limit that uses it. An open probe already reads hot.
  4. Store it with F4, Ctrl+S or ECU Controls → Store to ECU. Changes take effect straight away, but are lost at power-off until stored.
Calibration points
ModelLowHigh
EGX50.000 V = 0 °C4.800 V = 960 °C
EGX120.000 V = 0 °C5.000 V = 1250 °C

Calibrate to the amplifier's 0–5 V range, not to the probe's rating. Press U in PCLink to change units, including °C or °F.

Volts at a glance
EGTEGX5EGX12
100 °C0.50 V0.40 V
300 °C1.50 V1.20 V
500 °C2.50 V2.00 V
700 °C3.50 V2.80 V
850 °C4.25 V3.40 V
900 °C4.50 V3.60 V
960 °C4.80 V3.84 V
1000 °C4.00 V
1100 °C4.40 V
1250 °C5.00 V

A dash means past that model's range.

04See it and log it

05Optional: a warning light or protection

A GP Temperature can drive an output or feed a limiter.

  1. Warning light: a General Purpose Output, with SW Parameter 1 set to your GP Temperature, SW Cond 1 set to >, and your limit in the row below. On Delay and Off Delay are there too.
  2. Protection: GP RPM Limit 1 or 2 can put the EGT on a table axis, with Startup Lockout and Activation Delay.

06If something's wrong

PCLink logs “An Volt below Error Low Value”
Error Low is above 0 V. The EGX reads close to 0 V when cold, so set Error Low to 0.00 V, then clear the codes under ECU Controls. If one comes back, Store, power-cycle and clear it again.
GP Temperature shows a fixed value
The input is in fault, so PCLink shows the Error Value instead of the reading. Check the An Volt's status in Runtime Values.
Every sensor reads slightly wrong
Check the 5 V supply: it should measure very close to 5 V at the +5V pin. Fault code 74 is a 5 V supply error, usually from a mis-wired sensor.
It reads near full scale on a cold engine
The probe is unplugged or open. Both modules drive their output high when the probe circuit is open, so an open probe reads hot, not cold.
The reading jumps with revs, fans or the alternator
You have a grounded probe, or the black wire is on chassis ground. Fit an ungrounded probe and use the sensor ground.
It reads high once the engine bay heats up
The module is mounted somewhere too hot, or there's copper wire between the probe and the module.