Haltech's Nexus and Elite ECUs read an exhaust gas temperature amplifier on an analog voltage input (AVI), set up as Exhaust Gas Temperature 1 in NSP with a volts-to-temperature calibration. This guide covers which inputs work, the wiring, the NSP setup, and diagnostics and cylinder protection.

Checked against Haltech's NSP support articles and ECU pinouts, September 2026. Some of those articles are several years old, so a label can differ slightly.

00What you need

01Pick an input

Use an analog voltage input, an AVI. AVIs read 0–5 V. Most have a selectable 1 kΩ pull-up to 5 V, and it has to be off for an EGX.

02Wire it

EGX MODULE Yellow + Red − TYPE K PROBE MINI-K SOCKET Red — supply Black — sensor ground White — analog pin TO HALTECH
Probe on one side, three wires to the ECU on the other.
Output wires
WireEGX5EGX12
Red+5V sensor supply: “SENSOR +5V” on Nexus R5 and R3; “+5V DC” on Elite; pin A9 on T2/T1; C25 on Rebel LSSwitched 12 V
BlackSensor ground: “SIGNAL GND” on Nexus R5, “SIGNAL GROUND” on R3 and Elite; pin 11 on T2/T1, not pin 10; C26 on Rebel LSSensor ground: “SIGNAL GND” on Nexus R5, “SIGNAL GROUND” on R3 and Elite; pin 11 on T2/T1, not pin 10; C26 on Rebel LS
WhiteThe AVI you pickedThe AVI you picked

Probe side

03Set it up in NSP

  1. In NSP, tick EGT 1 under Exhaust Gas Temp on the Sensors page, or enable it under Enable Disable Functions.
  2. Open Sensors → Exhaust Gas Temperature 1 → Wiring. Set Input Type to Analogue - Voltage, pick your AVI with Exhaust Gas Temperature 1 Input → Edit, and set Pull Up to Disable. If it's your only EGT sensor, set Position to Unassigned.
  3. Open the Exhaust Gas Temperature 1 calibration and replace the example values. Set the two columns to 0.000 V = 0 °C and to your model's full-scale point from the table below.
  4. If NSP highlights Reboot Device in red, reboot the ECU.
Calibration points
ModelLowHigh
EGX50.000 V = 0 °C4.800 V = 960 °C
EGX120.000 V = 0 °C5.000 V = 1250 °C

Haltech's help screenshots show a calibration of 0.75 V = 0 °C and 4.50 V = 1250 °C. That's only an example; an EGX starts at 0.000 V = 0 °C.

NSP shows °C or °F according to Preferences → Units Options. If EGT 1 is already used, set up the next free EGT channel the same way.

Volts at a glance
EGTEGX5EGX12
100 °C0.50 V0.40 V
300 °C1.50 V1.20 V
500 °C2.50 V2.00 V
700 °C3.50 V2.80 V
850 °C4.25 V3.40 V
900 °C4.50 V3.60 V
960 °C4.80 V3.84 V
1000 °C4.00 V
1100 °C4.40 V
1250 °C5.00 V

A dash means past that model's range.

04See it and log it

05Optional: diagnostics and cylinder shutdown

NSP can flag a high EGT and cut a cylinder that runs too hot.

  1. Under Diagnostics, leave Raw Min and Raw Max off. The EGX reads close to 0 V when cold, and an open probe reads at the top of the range, the same as a real overheat, so neither voltage limit helps.
  2. Operating Max flags a temperature above a limit, with its own DTC.
  3. With one EGT per cylinder, Cylinder Shutdown can cut a cylinder above Max EGT after a Delay. The cut lasts until a reset or power cycle. An open probe reads hot, so it can cut its cylinder too.

06If something's wrong

It reads too high with the probe connected
Pull Up is still enabled, which skews the reading. Set Pull Up to Disable on the Wiring page.
It's wrong at every temperature
The example calibration is still loaded. Replace it with 0.000 V = 0 °C and your model's full-scale point.
It reads near full scale on a cold engine
The probe is unplugged or open. Both modules drive their output high when the probe circuit is open, so an open probe reads hot, not cold.
The reading jumps with revs, fans or the alternator
You have a grounded probe, or the black wire is on chassis ground. Fit an ungrounded probe and use the sensor ground.
It reads high once the engine bay heats up
The module is mounted somewhere too hot, or there's copper wire between the probe and the module.