ROSINA

Guide · EFILive

EGT on EFILive

EFILive logs a 0–5 V exhaust gas temperature amplifier through the analog inputs on FlashScan V2, the older unit. FlashScan V3 and AutoCal V3 have no analog inputs, so they can't read an EGX5 or EGX12 directly. If you have a V2, this guide covers the wiring, a calculated PID that turns volts into °C, and logging.

Checked against EFILive's V8 reference manual, its knowledge base and the FlashScan V2 documentation, September 2026.

00What you need

01Pick an input

FlashScan V2 has four analog inputs, A1 to A4, on AD-2 screw-terminal plugs. Each reads 0–5 V at 10-bit resolution, isolated from the rest of the unit.

02Wire it

EGX MODULE Yellow + Red − TYPE K PROBE MINI-K SOCKET Red — supply Black — sensor ground White — analog pin TO FLASHSCAN V2
Probe on one side. Supply goes to switched 12 V, and ground and signal to the FlashScan input.
Output wires
WireEGX5EGX12
RedIts own 5 V supply, because FlashScan has noneSwitched 12 V
BlackVehicle ground near the module, with the input's − terminal on the same pointVehicle ground near the module, with the input's − terminal on the same point
WhiteInput A1–A4, + terminalInput A1–A4, + terminal

Probe side

03Set it up in EFILive V8

  1. In EFILive V8, open [F2: Scan] → [F2: PIDs] and drag the external analog PID for your input (AD1 to AD4) into the selected PIDs.
  2. Open [Config] → Calculated PIDs (Ctrl+K). Add a group, four characters or fewer, then add a PID in metric units (°C).
  3. Click [Edit] and type return. Click your AD PID in the list on the right so EFILive inserts its exact name, then add *250 for an EGX12 or *200 for an EGX5. Click [Test]. Scripts are case-sensitive, and the AD PID must stay selected.
  4. For standalone logging on the FlashScan itself, set A/D PIDs to Yes in the device settings so it records every external analog PID.
Calibration points
ModelLowHigh
EGX50.000 V = 0 °C (32 °F)4.800 V = 960 °C (1760 °F)
EGX120.000 V = 0 °C (32 °F)5.000 V = 1250 °C (2282 °F)

EFILive recommends its built-in editor over editing the calculated PID file by hand. The multiplier is the full-scale temperature divided by the full-scale voltage, from the calibration points above.

Volts at a glance
EGTEGX5EGX12
100 °C / 212 °F0.50 V0.40 V
300 °C / 572 °F1.50 V1.20 V
500 °C / 932 °F2.50 V2.00 V
700 °C / 1292 °F3.50 V2.80 V
850 °C / 1562 °F4.25 V3.40 V
900 °C / 1652 °F4.50 V3.60 V
960 °C / 1760 °F4.80 V3.84 V
1000 °C / 1832 °F4.00 V
1100 °C / 2012 °F4.40 V
1250 °C / 2282 °F5.00 V

A dash means past that model's range.

04See it and log it

05If something's wrong

The inputs read 0 V
Check that FlashScan has 12 V from the OBD connector; the inputs don't work on USB power. Keep EFILive current too: a 2020 V8 bug read the analog inputs as 0 V.
Readings are offset or drift
Ground offset. Put the input's − terminal on the EGX's ground. If the inputs themselves are off, EFILive's Control Panel has Calibrate A/D, using stable 1–2 V and 3–5 V sources.
It reads near full scale on a cold engine
The probe is unplugged or open. Both modules drive their output high when the probe circuit is open, so an open probe reads hot, not cold.
The reading jumps with revs, fans or the alternator
You have a grounded probe, or the black wire is on chassis ground. Fit an ungrounded probe and use the sensor ground.
It reads high once the engine bay heats up
The module is mounted somewhere too hot, or there's copper wire between the probe and the module.