ROSINA

Type K thermocouple · 0–5 V analog out

EGA5 and EGA12 specifications

The output side is the same three wires as any pressure sensor — supply, ground, signal — so it wires into any analog input and calibrates with two points. Sold as a kit with a tested ungrounded probe, bung and fitting, or as the module on its own.

Specifications

EGA5 · EGA12
ParameterEGA5EGA12
Range0 – 960 °C0 – 1250 °C
Output5 mV/°C4 mV/°C
Zero0.000 V = 0 °C0.000 V = 0 °C
Supply5 V — the ECU's sensor rail8 – 16 V switched, 12 V nominal
Input protectionDirect inputSeries limits, RC filter and clamp diodes on both legs
Initial accuracy±3 °C at 25 °C±3 °C at 60 °C
Kit probeStainless, 5 mm, 0 – 1200 °CStainless, 5 mm, 0 – 1200 °C — the kit's ceiling, not the module's
Pro probeInconel, 3/16″ sealed, ungrounded tip, 1300 °C, ±1.1 °C SLEInconel, 1/8″ sealed, ungrounded tip, 1300 °C, ±1.1 °C SLE, 550 ms — reaches the full 1250 °C
Pre-turbo option+$20 — Inconel, 1/4″, sealed, ungrounded tip+$20 — Inconel, 1/4″ swaged to 1/8″, sealed, ungrounded tip, 500 ms
Probe mountWeld-in bung included — 1/8″-27 NPT, 304 stainlessWeld-in bung included — 1/8″-27 NPT, 304 stainless
No-weld option+$24.95 — M18 × 1.5 male to 1/8″ NPT female adapter, not stocked, so it adds a few days to dispatch. Fits an unused O2 port, and raises the probe: check stack height and insertion depth first.+$24.95 — M18 × 1.5 male to 1/8″ NPT female adapter, not stocked, so it adds a few days to dispatch. Fits an unused O2 port, and raises the probe: check stack height and insertion depth first.
Size36.3 × 27.5 × 15.6 mm, ASA-CF44 × 34 × 16.1 mm, ASA-CF

Output leads: red supply · black ground · white signal. Thermocouple, module only: yellow + · red −. Kits end in a mini-K socket.

Download the datasheet (PDF) Full specifications · wiring · calibration · fitting notes

Setup guides: wiring and software setup for Speeduino, MegaSquirt, Haltech, Link, AEM, Holley EFI, MaxxECU and more.

Warranty and support

12 months, replace, no questions asked.

The module is sealed against vibration, moisture and heat cycling.

Support: sales@rosinalabs.com. Include the model and what it is fitted to.

Full terms: rosinalabs.com/policies